600°, 320X240 thermal imager [aka Infrared camera] for displaying and capturing surface temperature of objects. The high temperature capability makes this unit especially suitable in industrial applications. Common use are in troubleshooting electrical installations, electro-mechanical equipment, process equipment and HVAC equipment. Increasingly used for housing inspection where heat loss and dampness is a consideration.
- Temperature range: -20°C to 600°C
- Accuracy: ± 2°C or 2% (whichever is greater)
- Detector type: 320 x 240 focal plane array, uncooled microbolometer
- Thermal sensitivity (NETD): ≤ 0.05°C at 30°C (50 mK)
- Infrared spectral band: 7.5μm to 14μm
- Minimum span: 2.5°C
- Visual camera: 2 megapixel resolution.
- IR-Fusion® information: Control over IR and visual light blending and/or Picture in Picture
- Voice annotation: 60 seconds maximum recording time per image
- Storage medium: SD memory card (2GB will store at least 1200 files)
- Fast charging internal LiIon battery will last one ‘typical’ day.
- Fluke SmartView software (included) for analysing images and creating reports.